Automation & Control

Automation & Control

Automation & Control

From plant floor to enterprise: resilient control, certified safety, and intelligent assets—delivered with documentation you can file.
Every system is engineered for cybersecurity, uptime, and lifecycle value, backed by IEC/ISA compliance, factory testing, and full-as-built documentation.

1) DCS — Distributed Control Systems

Positioning: The backbone of continuous/process control. We deliver scalable, redundant architectures with deterministic networks, batch capability, and open data integration.

Architecture & Features

  • Redundant controllers, networks, and power (1+1, 2N)
  • Remote/Marshalled I/O: HART-enabled, intrinsically safe options (Ex ia/ib)
  • Industrial Ethernet: OPC UA, Modbus TCP, PROFINET, EtherNet/IP; historian connectors
  • Batch & recipes: ISA-88 / IEC 61512; integrated historian & reporting
  • Advanced control: PID libraries, MPC, soft sensors, embedded analytics
  • Alarm management: ISA-18.2 / EEMUA 191 philosophy, KPIs, shelving & suppression
  • Cybersecurity: IEC 62443 defense-in-depth, role-based access, secure remote access, patch mgmt
  • Time sync: IEEE 1588 (IEC 61588) PTP for event fidelity

Standards & Good Practice

  • IEC 61131-3 languages (LD/FBD/ST/SFC)
  • ISA-95 / IEC 62264 (OT↔MES/ERP integration)
  • IEC 62443 (IACS cybersecurity)

Deliverables

  • Control narratives, cause & effect, alarm philosophy
  • Network & I/O drawings, cable schedules
  • FAT/SAT test scripts, maintenance & operator training

RFQ Checklist (DCS)
Process scope, I/O list (AI/AO/DI/DQ + HART), redundancy strategy, batch needs, integration points (MES/CMMS), cybersecurity level, FAT/SAT location & scope.

2) SIS — Safety Instrumented Systems

Positioning: Independent protection layers to reduce process risk to tolerable levels—designed, verified, and documented across the IEC 61511 safety lifecycle.

Core Concepts

  • SIL 1–3 targets via LOPA; Safety Requirement Specification (SRS)
  • Architectures: 1oo1, 1oo2, 2oo3 logic solvers & sensor/Final Element voting
  • PFDavg calculation, proof-test intervals, diagnostic coverage, HFT per IEC 61508/61511
  • Separation from BPCS/DCS; independent power and comms as required
  • Final elements: partial-stroke testing (PST), solenoid monitoring, position feedback
  • HIPPS, ESD, F&G integration with certified devices

Standards

  • IEC 61511 (process SIS lifecycle) / IEC 61508 (functional safety of E/E/PE systems)
  • SIL-capable devices and logic solvers with third-party certifications

Deliverables

  • SRS, LOPA reports, verification/validation plan
  • Proof-test procedures, bypass management, override logs
  • Safety manual packs, as-built architecture & cause/effect

RFQ Checklist (SIS)
Target SIL per SIF, demand rates, trip setpoints, proof-test interval/coverage, voting logic, bypass rules, reporting & cybersecurity segregation.

3) Instrumentation (Smart Field Devices)

Positioning: Accurate, reliable measurement with built-in diagnostics to cut downtime and calibration cost.

Measurement Portfolio

  • Pressure/DP/Level/Temp transmitters: HART, Foundation Fieldbus, Profibus PA
  • Flow: DP (ISO 5167), Coriolis (ISO 10790), Magnetic (ISO 6817), Ultrasonic (per app), Turbine (API MPMS 5.3)
  • Level: Radar (FMCW/pulse), guided wave radar, ultrasonic, displacer
  • Analytical: pH/ORP, conductivity, DO, TSS, gas analyzers (O₂, H₂S, C6+)

Compliance & Environments

  • Hazardous areas: ATEX/IECEx (IEC 60079), NEC 500/505
  • Ingress/Materials: IP66/67, 316/duplex wetted parts; NACE MR0175/ISO 15156 for sour service
  • Calibration: ISO/IEC 17025 traceability; NAMUR NE 43 (fault current) & NE 107 (status)

Smart Maintenance

  • Device management via FDI/EDD/DD; AMS integration; predictive diagnostics; loop audits

RFQ Checklist (Instrumentation)
Process media & conditions (T/P, viscosity, solids, chlorides), accuracy/turndown, hazardous area class, communication (HART/FF/PA), material certs, calibration & doc pack.

4) Control Valves (with Actuation & Positioning)

Positioning: Precise, reliable final control elements sized for actual service—not catalogue conditions—backed by emission and fire-safe certifications.

Sizing & Performance

  • IEC 60534-2-1 / ISA 75.01 Cv sizing; IEC 60534-8 noise/cavitation prediction
  • Characteristics: equal-percentage, linear, quick-open; rangeability & resolution
  • Seat leakage: FCI 70-2 (Classes I–VI)

Valve Families

  • Globe (single/multi-stage, low-noise/cavitation trims)
  • Ball (floating/trunnion, segment)
  • Butterfly (double/triple-offset metal-seated)
  • Angle & severe-service (anti-cavitation, anti-erosion)

Compliance & Options

  • Fugitive emissions: ISO 15848-1, API 624
  • Fire-safe: API 607 / ISO 10497
  • Cryogenic: BS 6364; Clean service: FDA/USP VI materials (on request)
  • Materials: WCB/LCB, CF8M/duplex/super duplex, alloys for chlorides/sour

Actuation & Positioners

  • Pneumatic, electric, hydraulic; ISO 5211 mounting
  • Digital positioners (HART/FF/Profibus), partial-stroke for ESD, tight shutoff options

RFQ Checklist (Control Valves)
Fluid, min/normal/max flow, ΔP & P/T envelope, line size/class, leakage class, emission spec, end connections, materials, actuator fail action, comms & diagnostics.

Integration & Services (How We De-Risk Delivery)

  1. Assessment → Architecture: I/O & SIF mapping, networks, segregation, cybersecurity zoning (IEC 62443).
  2. Standards Alignment: Control narratives (ISA-88), alarm philosophy (ISA-18.2), safety lifecycle (IEC 61511).
  3. Engineering & Build: Detailed design, cabinet build (IEC 60204-1), FAT with simulation and loop checks.
  4. Site & Handover: SAT/commissioning, cause-and-effect verification, proof-test baselines, operator training.

Lifecycle: Patch mgmt, backups, spares, KPIs; device analytics, proof-test scheduling, periodic SIL re-verification.

Quick “Spec-to-Quote” Template (paste into your RFQ)

  • Scope: DCS / SIS / Instruments / Control Valves (select all that apply)
  • Standards: (IEC 62443, IEC 61511, ISA-88/18.2, etc.)
  • Process Data: P/T, composition, corrosives, min/nom/max flow or demand
  • I/O & Networks: AI/AO/DI/DQ counts, HART/FF/PA, OPC UA/Modbus/PROFINET
  • Safety: SIF list, target SIL, voting, proof-test interval
  • Mechanical: Line size/class, MOC, leakage/emissions class, end connections
  • Docs/Tests: FAT/SAT, 3.1 certs, calibration packs, cybersecurity docs
  • Logistics: Incoterms, site constraints, required on-stream date

Instrumentation (Smart Field Devices)

Positioning: Accurate, reliable measurement with built-in diagnostics to cut downtime and calibration...

Read More

DCS , SIS

Distributed Control Systems Positioning: The backbone of continuous/process control. We deliver scalable,...

Read More

Control Valves (with Actuation & Positioning)

Positioning: Precise, reliable final control elements sized for actual service—not catalogue conditions—backed...

Read More