Automation & Control
From plant floor to enterprise: resilient control, certified safety, and intelligent assets—delivered with documentation you can file.
Every system is engineered for cybersecurity, uptime, and lifecycle value, backed by IEC/ISA compliance, factory testing, and full-as-built documentation.
1) DCS — Distributed Control Systems
Positioning: The backbone of continuous/process control. We deliver scalable, redundant architectures with deterministic networks, batch capability, and open data integration.
Architecture & Features
- Redundant controllers, networks, and power (1+1, 2N)
- Remote/Marshalled I/O: HART-enabled, intrinsically safe options (Ex ia/ib)
- Industrial Ethernet: OPC UA, Modbus TCP, PROFINET, EtherNet/IP; historian connectors
- Batch & recipes: ISA-88 / IEC 61512; integrated historian & reporting
- Advanced control: PID libraries, MPC, soft sensors, embedded analytics
- Alarm management: ISA-18.2 / EEMUA 191 philosophy, KPIs, shelving & suppression
- Cybersecurity: IEC 62443 defense-in-depth, role-based access, secure remote access, patch mgmt
- Time sync: IEEE 1588 (IEC 61588) PTP for event fidelity
Standards & Good Practice
- IEC 61131-3 languages (LD/FBD/ST/SFC)
- ISA-95 / IEC 62264 (OT↔MES/ERP integration)
- IEC 62443 (IACS cybersecurity)
Deliverables
- Control narratives, cause & effect, alarm philosophy
- Network & I/O drawings, cable schedules
- FAT/SAT test scripts, maintenance & operator training
RFQ Checklist (DCS)
Process scope, I/O list (AI/AO/DI/DQ + HART), redundancy strategy, batch needs, integration points (MES/CMMS), cybersecurity level, FAT/SAT location & scope.
2) SIS — Safety Instrumented Systems
Positioning: Independent protection layers to reduce process risk to tolerable levels—designed, verified, and documented across the IEC 61511 safety lifecycle.
Core Concepts
- SIL 1–3 targets via LOPA; Safety Requirement Specification (SRS)
- Architectures: 1oo1, 1oo2, 2oo3 logic solvers & sensor/Final Element voting
- PFDavg calculation, proof-test intervals, diagnostic coverage, HFT per IEC 61508/61511
- Separation from BPCS/DCS; independent power and comms as required
- Final elements: partial-stroke testing (PST), solenoid monitoring, position feedback
- HIPPS, ESD, F&G integration with certified devices
Standards
- IEC 61511 (process SIS lifecycle) / IEC 61508 (functional safety of E/E/PE systems)
- SIL-capable devices and logic solvers with third-party certifications
Deliverables
- SRS, LOPA reports, verification/validation plan
- Proof-test procedures, bypass management, override logs
- Safety manual packs, as-built architecture & cause/effect
RFQ Checklist (SIS)
Target SIL per SIF, demand rates, trip setpoints, proof-test interval/coverage, voting logic, bypass rules, reporting & cybersecurity segregation.
3) Instrumentation (Smart Field Devices)
Positioning: Accurate, reliable measurement with built-in diagnostics to cut downtime and calibration cost.
Measurement Portfolio
- Pressure/DP/Level/Temp transmitters: HART, Foundation Fieldbus, Profibus PA
- Flow: DP (ISO 5167), Coriolis (ISO 10790), Magnetic (ISO 6817), Ultrasonic (per app), Turbine (API MPMS 5.3)
- Level: Radar (FMCW/pulse), guided wave radar, ultrasonic, displacer
- Analytical: pH/ORP, conductivity, DO, TSS, gas analyzers (O₂, H₂S, C6+)
Compliance & Environments
- Hazardous areas: ATEX/IECEx (IEC 60079), NEC 500/505
- Ingress/Materials: IP66/67, 316/duplex wetted parts; NACE MR0175/ISO 15156 for sour service
- Calibration: ISO/IEC 17025 traceability; NAMUR NE 43 (fault current) & NE 107 (status)
Smart Maintenance
- Device management via FDI/EDD/DD; AMS integration; predictive diagnostics; loop audits
RFQ Checklist (Instrumentation)
Process media & conditions (T/P, viscosity, solids, chlorides), accuracy/turndown, hazardous area class, communication (HART/FF/PA), material certs, calibration & doc pack.
4) Control Valves (with Actuation & Positioning)
Positioning: Precise, reliable final control elements sized for actual service—not catalogue conditions—backed by emission and fire-safe certifications.
Sizing & Performance
- IEC 60534-2-1 / ISA 75.01 Cv sizing; IEC 60534-8 noise/cavitation prediction
- Characteristics: equal-percentage, linear, quick-open; rangeability & resolution
- Seat leakage: FCI 70-2 (Classes I–VI)
Valve Families
- Globe (single/multi-stage, low-noise/cavitation trims)
- Ball (floating/trunnion, segment)
- Butterfly (double/triple-offset metal-seated)
- Angle & severe-service (anti-cavitation, anti-erosion)
Compliance & Options
- Fugitive emissions: ISO 15848-1, API 624
- Fire-safe: API 607 / ISO 10497
- Cryogenic: BS 6364; Clean service: FDA/USP VI materials (on request)
- Materials: WCB/LCB, CF8M/duplex/super duplex, alloys for chlorides/sour
Actuation & Positioners
- Pneumatic, electric, hydraulic; ISO 5211 mounting
- Digital positioners (HART/FF/Profibus), partial-stroke for ESD, tight shutoff options
RFQ Checklist (Control Valves)
Fluid, min/normal/max flow, ΔP & P/T envelope, line size/class, leakage class, emission spec, end connections, materials, actuator fail action, comms & diagnostics.
Integration & Services (How We De-Risk Delivery)
- Assessment → Architecture: I/O & SIF mapping, networks, segregation, cybersecurity zoning (IEC 62443).
- Standards Alignment: Control narratives (ISA-88), alarm philosophy (ISA-18.2), safety lifecycle (IEC 61511).
- Engineering & Build: Detailed design, cabinet build (IEC 60204-1), FAT with simulation and loop checks.
- Site & Handover: SAT/commissioning, cause-and-effect verification, proof-test baselines, operator training.
Lifecycle: Patch mgmt, backups, spares, KPIs; device analytics, proof-test scheduling, periodic SIL re-verification.
Quick “Spec-to-Quote” Template (paste into your RFQ)
- Scope: DCS / SIS / Instruments / Control Valves (select all that apply)
- Standards: (IEC 62443, IEC 61511, ISA-88/18.2, etc.)
- Process Data: P/T, composition, corrosives, min/nom/max flow or demand
- I/O & Networks: AI/AO/DI/DQ counts, HART/FF/PA, OPC UA/Modbus/PROFINET
- Safety: SIF list, target SIL, voting, proof-test interval
- Mechanical: Line size/class, MOC, leakage/emissions class, end connections
- Docs/Tests: FAT/SAT, 3.1 certs, calibration packs, cybersecurity docs
- Logistics: Incoterms, site constraints, required on-stream date
Instrumentation (Smart Field Devices)
Positioning: Accurate, reliable measurement with built-in diagnostics to cut downtime and calibration...
Read MoreControl Valves (with Actuation & Positioning)
Positioning: Precise, reliable final control elements sized for actual service—not catalogue conditions—backed...
Read More